FCR CAPSULA XLII

Rapid processing and precise image reading ideal for X-ray images including mammograms
Introducing a newly upgraded FCR CAPSULA XL II designed with a new form and equipped with state-of-the-art functions including an optional capability of 50-micron reading with high resolution imaging plates (HR-V and HR-VI).
OverView
Features
- Compact with high efficiency
- All-in-one unit for all diagnostic imaging needs
- Easy operations monitored on screen
- Image display and processing — CR console
- Featuring Image Intelligence™ technology
Mammography applications (optionalFCR CAPSULA XL II with Imaging Plate HR-VI has cleared FDA* / 510k** for mammography applications in the U.S.A market as “ASPIRE CR FOR MAMMOGRAPHY SYSTEM (CRM)”. The “ASPIRE CR FOR MAMMOGRAPHY SYSTEM (CRM)” is a full-field digital mammography system consisting of the three main components;
FCR Capsula XLII (CR-IR 359), Imaging Plate HR-VI and Console (CR-IR 348 CL).
Features
One of the FCR key components is an Imaging Plate, or IP, that is used in place of X-ray film to easily digitize X-ray images. The FCR CAPSULA XLII features the IP in an unprecedented compact frame, as it incorporates over 70 years of Fujifilm’s extensive technology and know-how.
CAPSULA, meaning small box in Latin, has been cleverly trimmed to be smaller and lighter, boosting flexibility on installation and layout, while maintaining the specifications for a broad range of diagnostic imaging needs from general radiography to pantomography. Plus, the optional capability of 50-micron reading with the HR-V or HR-VI can be utilized to visualize finer and more minute structures for better diagnosis.
Compact with high efficiency
FCR CAPSULA XLII enables extremely high throughput of up to approximately 94 IPs/hr.* and the time to display the image on the CR Console monitor is approximately 23 sec., in spite of its compactness.
![[Image] Compact with high efficiency](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_features_01.jpg)
All-in-one unit for all diagnostic imaging needs
Three types of IP cassettes (Type CC, LC and CH**) can cover various imaging such as chest, lumbar spine, pantomography (15 × 30 cm), and extremities. Virtually all imaging requirements can be satisfied with the single unit.
![[Image] All-in-one unit for all diagnostic imaging needs](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_features_02.jpg)
Easy operations monitored on screen
Capable of automatically starting the IP reading and image processing when the IP cassette is inserted, the system is designed to complete the IP reading cycle with simple operations. Setting parameters can be changed with the buttons on the monitor screen. The screen can also display the status and the time remaining to complete the IP reading process for user-convenience.
![[Image] Easy Operations monitored on Screen](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_features_03.jpg)
Image display and processing — CR Console
The multi-function console handles all complex procedures of digital X-ray imaging — patient ID, image reviewing, processing and printing, DICOM interface, and more — as well as quality assurance functions all within a single workstation.
Featuring Image Intelligence™ technology
Fujifilm’s unique Image Intelligence™ processing technologies to realize clear and crisp images.
![[Logo] Image Intelligence™](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/logo_01.gif)
Mammography applications*** (optional)
FCR CAPSULA XLII equipped with the optional capability of 50-micron reading with the HR-V or HR-VI and the IP cassette type CH can visualize finer and more minute structures.
![[Image] Mammography applications](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_features_06_01.jpg)
HR-VI*4 is improved type IP from HR-V, and has the following additional features.
Image quality improvement
By using Fujifilm’s imaging plate technologies, HR-VI’s image quality improved compared to HR-V.
Compatible with MAMMOASCENT AWS-c
The MAMMOASCENT AWS-c optimizes your mammography examinations with its advanced design and features. Correspondence to Fujifilm Mammography QC Program with 1 shot phantom.
![[Image] Compatible with MAMMOASCENT AWS-c](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_features_06_02.jpg)
Compatible with Fujifilm Mammography QC Program
Fujifilm Mammography QC Program is a dedicated quality control program applicable to Fujifilm digital mammography system. This program enables the system to keep a stable image quality for both screening and diagnosis.
![[Image] Compatible with Fujifilm Mammography QC Program](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_features_06_03.jpg)
Notes
Specifications
Standard Components | FCR CAPSULA XLII Image Reader Unit (Model: CR-IR 359) AC power cord |
---|---|
Other System Components | Optional upgrade kit for 50-micron reading with HR-V or HR-VI IP cassette type CC, LC, CH CR Console, CONSOLE ADVANCE*, AWS-c Dry Imager: DRYPIX 2000, 4000, 7000 |
Supplies |
|
Number of Stacker | 1 |
Reading Gray Scale | 12 bits |
Network | 10 Base T / 100 Base TX |
Dimensions (W × D × H) | 590 × 380 × 810 mm (23″ × 15″ × 32″) |
![]() |
|
Weight | 99 kg (218 lbs.) |
Power Supply Conditions | Single phase 50 – 60 Hz AC 120 – 240 V ±10% 5 A (max) |
Environmental Conditions |
|
Time Required for IP Feed / Load:
IP Type | Required Time | |
---|---|---|
ST-VI | 35 × 43 cm (14″ × 17″) | Approx. 58 (41) sec. |
ST-VI | 35 × 35cm (14″ × 14″) | Approx. 52 (38) sec. |
ST-VI | 10″ × 12″ | Approx. 49 sec. |
ST-VI | 8″ × 10″ | Approx. 41 sec. |
ST-VI | 24 × 30 cm | Approx. 48 sec. |
ST-VI | 18 × 24 cm | Approx. 39 sec. |
ST-VI | 15 × 30 cm | Approx. 49 sec. |
HR-V | 24 × 30 cm** | Approx. 59 sec. |
HR-V | 18 × 24 cm*** | Approx. 51 sec. |
HR-VI | 24 × 30 cm** | Approx. 59 sec. |
HR-VI | 18 × 24 cm*** | Approx. 51 sec. |
- Under “Required Time” in the table above, figures in parentheses are at high-speed mode.
- Image erase time on IP is directly related to the exposure made. It is assumed to be at 25 mR for ST-VI and 600 mR for HR-V.
- The performance described above shows typical values. It varies depending on the exposure level.
Processing Capacity
IP Type | Required Time | |
---|---|---|
ST-VI | 35 × 43 cm (14″ × 17″) | Approx. 62 (87) IPs / hr. |
ST-VI | 35 × 35cm (14″ × 14″) | Approx. 70 (94) IPs / hr. |
ST-VI | 10″ × 12″ | Approx. 73 IPs / hr. |
ST-VI | 8″ × 10″ | Approx. 87 IPs / hr. |
ST-VI | 24 × 30 cm | Approx. 75 IPs / hr. |
ST-VI | 18 × 24 cm | Approx. 92 IPs / hr. |
ST-VI | 15 × 30 cm | Approx. 73 IPs / hr. |
HR-V | 24 × 30 cm** | Approx. 61 IPs / hr. |
HR-V | 18 × 24 cm*** | Approx. 70 IPs / hr. |
HR-VI | 24 × 30 cm** | Approx. 61 IPs / hr. |
HR-VI | 18 × 24 cm*** | Approx. 70 IPs / hr. |
- Figures in parentheses and conditions are the same as those of “Time Required for IP Feed / Load”.
- The time required to change the cassette is assumed to be 0 (zero) seconds.
Time to Display on CR Console:
- Approx. 42 sec. in case of 35 × 43 cm (ST-VI) with 100-micron reading
- Approx. 32 sec. in case of 18 × 24 cm (HR-V)*** with 50-micron reading
Time to Print on DRYPIX 4000 through network via CR Console:
- Approx. 145 sec. in case of 35 × 43 cm (ST-VI) with 100-micron reading
- Approx. 140 sec. in case of 18 × 24 cm (HR-V)*** with 50-micron reading
Reading Specification
Inches | Metric | Reading Specification | |
---|---|---|---|
Standard Pixel-density | High Pixel-density | ||
High-speed mode | Standard mode | ||
14″ × 17″ (ST-VI) | 35 × 43 cm (ST-VI) | 5 pixels / mm | 10 pixels / mm |
14″ × 14″ (ST-VI) | 35 × 35 cm (ST-VI) | 5 pixels / mm | 10 pixels / mm |
10″ × 12″ (ST-VI) | 24 × 30 cm (ST-VI) | — | 10 pixels / mm |
8″ × 10″ (ST-VI) | 18 × 24 cm (ST-VI) | — | 10 pixels / mm |
— | 15 × 30 cm (ST-VI) | — | 10 pixels / mm |
— | 24 × 30 cm (HR-V)** | — | 20 pixels / mm |
— | 18 × 24 cm (HR-V)*** | — | 20 pixels / mm |
— | 24 × 30 cm (HR-VI)** | — | 20 pixels / mm |
— | 18 × 24 cm (HR-VI)*** | — | 20 pixels / mm |
IP Cassette
![[Image] IP Cassette](https://www.fujifilm.com/products/medical/products/computed_radiography/capsula_xl2/img/index/pic_spec_02.jpg)
Imaging Plate and Cassette
IP ST-VI
FCR Imaging Plate for general purpose
14″ x 17″ (35.4 x 43.2 cm)
14″ x 14″ (35.4 x 35.4 cm)
10″ x 12″ (25.7 x 30.5 cm)
8″ x 10″ (20.3 x 25.4 cm
IP HR-V
- FCR Imaging Plate for single-sided mammography reading
24 x 30 cm
18 x 24 cm
IP ST-BD
- Standard Dual-Side Imaging Plate
24 x 30 cm
18 x 24 cm
IP HR-BD
- FCR Imaging Plate for dual-sided mammography reading
24 x 30 cm
18 x 24 cm
IP Cassette Type CC
- FCR standard cassette with or without lead foil backside
14″ x 17″ (35.4 x 43.2 cm)
14″ x 14″ (35.4 x 35.4 cm)
10″ x 12″ (25.7 x 30.5 cm)
8″ x 10″ (20.3 x 25.4 cm)
15 x 30 cm
IP Cassette Type CH
FCR special cassette for IP HR-V reading
24 x 30 cm
18 x 24 cm
IP Cassette Type DS
FCR cassette for IP ST-BD
24 x 30 cm
18 x 24 cm
IP Cassette Type DM
FCR cassette for dual-sided mammography reading
24 x 30 cm
18 x 24 cm
IP Cassette Type LC
FCR long view cassette for Scoliosis
35.4 x 124.5 cm
35.4 x 101.7 cm
35.4 x 83.0 cm
25.2 x 58.0 cm
24.0 x 57.0 cm
IP Cassette Type PC
FCR special cassette for Linac/Oncology
14″ x 17″ (35.4 x 43.2 cm)
14″ x 14″ (35.4 x 35.4 cm)